This blog post is a prettified version of my notes on how to deploy vSphere 7.0 with Kubernetes. You can use the same process to install any nested environment. for example, this architecture is perfect to install PKS as well **
Hosted environment setup
The base architecture of the nested environment is NSX-T nested within NSX-T with a nested vSAN deployment for storage. The hosted environemnt should have at least three physical ESXi servers and NSX-T 2.5+ installed and configured. You can change the architecture to implement vDS port groups based deployment instead of NSX-T logical segments. Pay attention to the configuration of the hosted network and configure the port group as if they are the NSX-T logical segments.
Hosted NSX
The ESXi server should be prepared for NSX-T installation with an overlay and uplink networks. The hosted NSX-T would be configured with a T0 to uplink the communication.
The following diagram represents the NSX-T configuration:

IP Pools:
Name | IP Range |
---|---|
Management |
12.12.12.0/24 |
Uplink | 12.12.13.0/24 |
Ingress | 12.15.0.0/16 |
Egress | 12.16.0.0/16 |
POD’s | 12.13.0.0/16 |
Nodes | 12.14.0.0/16 |
Start by creating a T1 router for the nested environment under the main T0


Create two logical segments profiles to enable MAC learning and disable SW security. Create one for MAC and one for security

Create two segments for the nested environment. One for Uplink and one for Management and nested overlay

When creating the segments connect the segment into the T1 and change the segment profile to the new ones you created with MAC learning and without any SW security.

Finish the configuration of the T1 for the nested environment
the most important step of the preparation is SW profile. without the configuration of the segment profile, the nested T0 won’t be able to connect externally.
Create static routes on the T1 router for the nested environment. The following static routes need to be created: Ingress, Egress, Pods and Nodes

Add Route advertisement

Hosted ESX
Hosted ESXi Setup – if you would like use vSAN in the nested environment you need to run the following command:
esxcli system settings advanced set -o /VSAN/FakeSCSIReservations -i 1 |
Nested environment setup
Prepare the nested environment.
- If you don’t have any domain, NTP, DNS or you want to use internal services for all, you need to create a Windows server with all of these roles to leverage them in the nested environment. they can all be under the same Windows server and you can use the same machine as a Jump server for the environment as well.
- Important – before you start the installation, create DNS records for all components ESXis, VCSA, NSX Manager and NSX edge.
- If you don’t want to use the WSL of Windows you will need a Linux jump machine to connect and manage the k8s cluster and service.
- The installation of the nested environment will present an external service to the internal environment. That means that the NSX manager, the edge, the vCenter and the domain will be installed in the hosted environment and not internally. See the diagram above to better understand the architecture of the nested environment.
- Configure the ESXi VM
- Create a new virtual machine

- Choose a name, compute and storage resources, compatibility and in the guest OS, choose Other – VMware ESXi 6.5 or later

- In the customize HW there are several important things to do. The base we will use vSAN in the nested environment
- CPU configuration – enable Expose HW assisted virtualization

- Configure memory according to what you have in the hosted environment.
- Hard disks – we will add two disks on top of the system on for the use of SAN. I’m adding a small one for cache and a larger one for capacity

- Add another network device. Change the network configuration to connect to the management switch you created in the nested NSX. One vNIC will be for management and the other one, vmnic1, for the nested NSX overlay.

- Important – change the VM boot option to BIOS, without doing that you won’t be able to boot from CD (iso image)

- Now you can clone the VM four times with different ESX names before the installation of ESXi! if you will clone the VM after installation vSAN and other things won’t work.
- To start the installation I recommend installation of the VMRC (for console access to the VM’s) https://my.vmware.com/group/vmware/details?downloadGroup=VMRC1110&productId=974
- Run the VM and remote control into the ESX. the set of procedures described in the next steps should be replicated to each ESX you have in the nested environment. Every step here is important for the right function of the environment.
- Open VMRC and mount the ISO of the ESX 7.0 from https://my.vmware.com/group/vmware/info/slug/datacenter_cloud_infrastructure/vmware_vsphere/7_0
- Start the configuration of the ESX installation

- Configure the small disk for the system installation

- Configure password and go to configure the management network

- Configure the IP, GW and DNS for the ESX. Important – configure the DNS and the domain suffix



- Don’t forget to commit the changes and press Y

- Continue the configuration on the ESX web browser
- On the networking configure the virtual swit5ch for 9000 MTU and change the security settings to accept everything

- On the VMkernel tab, configure vmk0, change the MTU to 1800 and add vMotion to the settings below **because we are changing the management VMkernel you will experience a short disconnect to the ESX **
we will use the VM network and the default VMkernel for everything. vMotion, Management and VSAN.

- Important – change the TCP/IP stack and add the domain configuration to the Default TCP/IP stack

- Go to the Manage section, in Service, start the SSH service (TSM-SSH)
- Repeat the configuration for all ESX’s and don’t add them to the vCenter before finishing the configuration according to the upper flow
- Configure the vCSA
- Download the vCSA appliance 7.0 and ESXi 7.0 from My VMware https://my.vmware.com/group/vmware/info/slug/datacenter_cloud_infrastructure/vmware_vsphere/7_0
- Deploy the vCSA from a win machine that has access to the management logical SW and can resolve the name of the vCSA. the vCSA has two steps, in the first one configure the hosted vCSA as the host to create the nested vCSA in. configure the IP of the vCSA according to the DNS record and be sure you have connectivity to the management logical switch. Important – configure NTP in the installation that is up and in sync.



- You can stay with tiny installation if the NSX installation is external and not embedded

- You can enable thin disk mode as its a lab environment.

- Choose the management logical switch and configure the network parameters

- That is the first step of the installation if everything is right and you have connectivity and name resolution for the vCSA machine you will get to the next screen:

- Continue to the configuration of the next step and configure the NTP and enable SSH

- Configure the SSO domain for the nested environment.

- Click OK to finish the installation

- Connect to the vCSA to start the configuration of the nested environment.

- you need a set of licenses for the nested env. license for vCenter, vSphere with k8s and VSAN

- Create a new Datacenter and a new Cluster, don’t configure anything on the cluster side yet we will do that later.


- After you finish the ESX configuration according to the steps above, you can add them into the cluster we created

- Add the ESX servers with the FQDN and accept the certificate message
- Get the servers out of maintenance mode

- to configure the vSAN, DRS and HA (all needs to be enabled for k8s services) we need to enable vSAN on the VMkernel on each ESXi. go to Configure in each ESX, VMkernel adapters and edit VMkernel0

- check again the MTU (should be 1800) and check the vSAN on the button. do that for all ESX’s before enabling vSAN.
- go to the Cluster and press configure, go to vSAN services and press Configure. stay with the default configuration:


- claim the smaller disks to cache (change the Drive type to be Marked as Flash) and the larger ones for capacity

- next and finish. check the Storage on the vCenter after the tasks are finished to see the vsanDatastore with 1TB of capacity (with 4 ESX’s)

- now we need to TAG the vsanDatastore to use it as part of our vSphere with k8s env. the system will create a storage class in the supervisor cluster according to that tags. right-click the vsanDatastore and choose Assign Tag

- Add Tag – add Tag Category

- Add the Tag and the new category

- don’t forget to assign the Tag to the vsanDatastore

- create a storage policy based on the Tag we created. Click Menu – Policies and Profiles – VM Storage Policies

- enable tag based placement rules

- choose the Tag category we created in the steps before and browse tags to choose the k8s-storage-policy tag

- choose the vsanDatastore as the Datastore to use and click finish.
- go to the Cluster configuration in the vCenter and enable DRS and HA on the cluster


- the vCenter and ESX’s are ready. now for the network side with the deployment and configuration of the nested NSX.
- configure the nested NSX
- download the NSX unified appliance 3.0 and NSX edge ova’s from My VMware https://my.vmware.com/group/vmware/info/slug/networking_security/vmware_nsx_t_data_center/3_x
- deploy the NSX unified appliance in the hosted vCSA

- medium side manager is fine for nested env. the EDGE must be at least Large

- choose the management SW you created in the hosted env.

- the passwords for the Root and Admin users must be completed and long, without that you will have problems to manage the manager machine

- the network configuration should be according to the hosted env. management IP from the logical SW in the hosted env. It’s important to configure a proper DNS and NTP


- enable SSH as we will need to configure the EDGE connectivity after the installation.
- deploy the NSX Edge in the hosted vCSA

- IMPORTANT – DEPLOY LARGE EDGE (at least) if you want to use the k8s services

- the network configuration should be two vNICs to management and two for Uplink. both SW’s from the hosted network

- the passwords for the Root and Admin users must be completed and long, without that you will have problems to manage the manager machine

- the network configuration should be according to the hosted env. management IP from the logical SW in the hosted env. It’s important to configure a proper DNS and NTP


- NSX configuration
- after the deployment you will need to login to the NSX manager to enter the license under System – Licenses to be able to join the EDEG to the manager

- SSH to the manager and the edge. in the nsx manager run the following command:
openso-pacific-nsx-mgr> get certificate api thumbprint e82de2f251cdf59107f38e9afbe379673cc24a5b35c46a015788e48ddcacecd1
- we will use the output to join the EDGE into the management plane. in the EDGE run the following command:
openso-nsx-edge> join management-plane 12.12.12.10 thumbprint e82de2f251cdf59107f38e9afbe379673cc24a5b35c46a015788e48ddcacecd1 username admin
- insert the admin password and you should be able to see the following output after running the following command

- check connectivity with get managers command
openso-nsx-edge> get manager - 12.12.12.10 Connected (NSX-RPC) *
- now to configure the overlay and uplink in the nested env. first, the creation of the transport zones must be with “Nested=true” value to have the nested connectivity. install postman or create an API call to create the overlay and VLAN transport zones.
- with postman we will create a POST command for each TZ one for VLAN and one for Overlay with the URL https://12.12.12.10/api/v1/transport-zones/ and body:
{ "description":"VLAN", "display_name": "VLAN", "nested_nsx": true, "host_switch_name": "VLAN", "transport_type": "VLAN" }
{ "description":"Overlay", "display_name": "Overlay", "nested_nsx": true, "host_switch_name": "OVERLAY", "transport_type": "OVERLAY" }


- now to add the vCenter to the management plane of the NSX. in the NSX manager go to System – Fabric – Computer Managers. Importnat – check the Enable Trust mode

- create a new IP pool for the overlay connectivity, that’s not exposable, you can choose whatever you want. go to Networking – IP Address Pools add IP address pool

- add subnet by clicking on set and add subnet – IP range


- now to create a transport node profile for the ESX’s, go back to System – Fabric – Profiles – Transport zones profile

- choose the new overlay transport zone we created in the TZ section. NIOC will stay default. Uplink profile will be “nsx-edge-single-nic-uplink-profile”, we don’t use HA in our nested env. everything is on single NIC. LLDP is Disable.

- choose the IP Pool you created before and in the Pysical NIC’s enter vmnic1 and press enter. that will configure the second vmnic of the nested ESX’s to connect to the overlay network

- go to the Nodes to configure the transport zone profile to the ESX’s

- check the cluster level and choose the Configure NSX to configure the TZ profile and press apply

- check the status of the server after the configuration it should all be up and running

- now to configure the EDGE node transport zones. in the EDGE transport zone, choose the edge and press Edit
- Configure the Overlay with the same parameters we configured to the ESX’s. in the Virtual NIC’s choose fp-eth0 that should be the second VNIC with the Management SW connectivity 12.12.12.0/24

- add a second SW for the Uplink and configure the VLAN transport zone according to the PrintScreen. the Virtual NIC’s should be the third VNIC with the Uplink SW connectivity (the second hosted segment) 12.12.13.0/24

- go to the EDGE Clusters and add an Edge Cluster. add your only EDGE to the cluster and apply.

- check the connectivity of the Overlay by connecting to one of the ESX’s and run the following command
[root@openso-pacific-esx-01:~] esxcfg-vmknic -l
- the output should be the IP’s of the VMkernels

- vmk10 is the overlay network and we can see the IP from the IP Pool that was assigned. now ping the other ESX’s and the NSX EDGE with the following command
the command will ping from vmk10 with an MTU of 1600 to check the functionality of the overlay will work properly. the IP’s for the rest of the ESX’s and the EDGE will be sequential 10-11-12-13 for ESX’s and 14 for the EDGE[root@openso-pacific-esx-01:~] vmkping ++netstack=vxlan -s 1572 -d -I vmk10 192.168.113.11

- we can see there is connectivity between all components, we can start the configuration of the Uplink to the hosted T0.
- configure the Uplink connectivity from the Nested to the Hosted env.
- first, add Segment, give it a name “Uplink”, don’t connect the Segment yet, change the transport zone to the new VLAN transport zones we created and add VLAN0 to the VLAN box

- save the segment and create a new nested T0 in the Networking – T-0 Gateways section.
- configure the HA Mode to Active Standby (we have only one EDGE) and change the Fail Over to Preemptive, choose the EDGE cluster you created and the the EDEG node and save.

- add the default static route to the next hop. the next hop is the Uplink SW connected to the T1 of the hosted network. click set on the static route under ROUTING section


- Apply and save the configuration.
- add T0 interface to connect the Uplink Segment. click set interface and add an interface, configure the name, IP Address from the Uplink SW connected to the hosted T1, choose the Edge Node and save the configuration.

- Add route distribution to the nested T0



- check the connectivity to the Nested T0 by pinging the Uplink port Interface. ping to the Uplink interface of the hosted T1 12.12.13.1 and the Uplink interface of the nested T0 12.12.13.2 you should get reply from both

- the configuration of the Overlay and Uplink networks are complete. the networking is ready for vSphere with k8s enablement.
- configure the Kubernetes Supervisor Cluster
- assign licenses to the Hosts, vCenter and VSAN

- configure the Supervisor cluster by clicking the Workload Management under Menu

- Enable and choose the Cluster and click next. if the Cluster isn’t shown in the “Compatible” list, check the configuration according to this document. especially check the DNS configuration, DRS and HA

- in the Cluster setting, we can choose the Tiny option as it just for POC or LAB use case

- configure the Networking with the parameters we created. choose the VM Network for the Management control plane and start the IP from 12.12.12.100

- choose the vDS (it seems blank but you can choose that), EDGE Cluster and configure the Segments for Pod, Node, Ingress and Egress according to the static route and IP pools we configured in the network

- choose the Storage policy we created with the Tag for k8s-storage-policy in the next step

- review and finish the installation. the cluster will be configured in the background. that can take some time to finish

- once the configuration is done you can create the first Namespace for the sup cluster

- click Create Namespace and choose the cluster

- create a namespace with the name blog and connect to the cluster by getting the information from the Open link in the Status box

- follow the steps by downloading the kubectl vSphere plugin and run the command in a linux/windows machine that can connect to the supervisor cluster
kubectl vsphere login --server=https://12.15.80.1/ --insecure-skip-tls-verify -u administrator@vsphere.local
- now you can interact with kubectl with the cluster
localadmin@server:~$ kubectl get ns NAME STATUS AGE blog Active 14m default Active 49m kube-node-lease Active 50m kube-public Active 50m kube-system Active 50m vmware-system-capw Active 49m vmware-system-csi Active 49m vmware-system-kubeimage Active 49m vmware-system-nsx Active 49m vmware-system-registry Active 49m vmware-system-tkg Active 49m vmware-system-ucs Active 49m vmware-system-vmop Active 49m localadmin@server:~$
localadmin@server:~$ kubectl get nodes NAME STATUS ROLES AGE VERSION 421e5216577cdec079fc453e77b737f2 Ready master 44m v1.16.7-2+bfe512e5ddaaaa 421e7b33b1dbd5a65096cd03ef26239d Ready master 44m v1.16.7-2+bfe512e5ddaaaa 421ec8b0ea489db816a08083e009e066 Ready master 50m v1.16.7-2+bfe512e5ddaaaa openso-pacific-esx-01.lab.local Ready agent 28m v1.16.7-sph-4d52cd1 openso-pacific-esx-02.lab.local Ready agent 28m v1.16.7-sph-4d52cd1 openso-pacific-esx-03.lab.local Ready agent 28m v1.16.7-sph-4d52cd1 openso-pacific-esx-04.lab.local Ready agent 28m v1.16.7-sph-4d52cd1 localadmin@server:~$
- you can pull my git repo to install some sample apps and check the capabilities of the supervisor cluster git clone https://github.com/0pens0/tanzu_demo.git
localadmin@server:~$ git clone https://github.com/0pens0/tanzu_demo.gitCloning into 'tanzu_demo'...remote: Enumerating objects: 32, done.remote: Counting objects: 100% (32/32), done.remote: Compressing objects: 100% (26/26), done.remote: Total 32 (delta 12), reused 22 (delta 6), pack-reused 0Unpacking objects: 100% (32/32), done.localadmin@server:~$
- the blog.yaml will implement the deployment of a blog with persistence data. first, configure the storage policy to the Namespace
- after the configuration of the storage policy, you can see the Storage Class object that was created in the k8s side
localadmin@server:~/tanzu_demo$ kubectl get scNAME PROVISIONER AGEk8s-storage-policy csi.vsphere.vmware.com 79s
- if needed you can add permissions from the SSO domain of the vCenter and also quotas for CPU, Memory and Storage limitations.
- apply the blog.yaml on the blog namespace with the following command and check for pod, svc and pvc status
localadmin@server:~/tanzu_demo$ kubectl create -f blog.yaml -n blog
browse the app with the LB SVC IP
- the browsing of the app won’t work. by default, the NSX is configuring deny rules between the namespaces and management. add an any any role to enable communication in the distributed FW security section
- Publish the new rule and browse the app again
**Important message – that’s NOT a supported architecture, that’s just for POC’s. Lab’s. Test’s etc. **